All partitions containing wireless transmitters must be placed in the test mode for sensitivity
reduction of the RF receiver (50% sensitivity). Otherwise, the RF receiver remains at full strength.
For multi-partition systems, make sure all partitions are disarmed before entering this mode.
Do not conduct this test with your hand wrapped around the transmitter, as this will cause
inaccurate results.
To enter the Go/NoGo Test, perform the following steps:
Step
1
2
3
4

Trouble Conditions

Supervisory Messages
A display of "SUPV" accompanied by a zone number (001-128) and an alpha descriptor (if
programmed) indicates that a fire supervisory condition exists on that zone. This means
that the operation of the fire alarm system may be compromised.
Check or Trouble Messages
A display of "CHECK" or "TRBL" (as per field 1*07) accompanied by a zone number (001-
128) and an alpha descriptor indicates that a problem exists with that zone. Zone trouble
may be caused by one of the following conditions:
"CHECK" accompanied by a numeric display of "6XX," where XX = 01-32, indicates a
trouble on a 4204CF Supervised Bell Output (corresponding relay number 01-32).
Action
Enter [Installer Code] + [5] TEST.
Once transmitters are placed in their desired locations and the approximate
length of wire to be run to sensors is connected to the transmitter's screw
terminals, fault each transmitter.
If a single receiver is used, the keypad will beep three times to indicate signal
reception. If two receivers are used, the keypad will beep once if the first
receiver received the signal, twice if the second receiver received the signal,
and three times if both receivers heard the signal (which is desirable for
redundant configurations).
If the keypad does not beep, reorient or move the transmitter to another
location. Usually a few inches in either direction is all that is required.
Mount the transmitter according to the instructions provided with the
transmitter.
Exit the mode by entering [Installer Code] + [1] OFF.
A hardwired fire zone is open (broken wire)
A Day/Night zone (zone type 5) is faulted
A polling loop zone is not seen by the control panel
A polling loop zone has been tampered (cover removed on a 4190)
A wireless zone has not checked in during the time programmed in field 1*31
A 5800 Series transmitter has been tampered (cover removed)