VISTA-128B Installation and Setup Guide
Programming the Vista Gateway Module
See the PassPoint ACS instructions to program the Vista Gateway Module.
Access Control of an Entry/Exit Point Using VistaKey or PassPoint
The control can send entry and exit requests to the VistaKey or PassPoint ACS utilizing
keypads, and button type (BR) RF transmitters. A zone is programmed with a response type
27 (Access Point) and an appropriate input type (console, RF).
Using the Alpha Keypad
The following entries at the keypad provide access of a door.
•
Code + #73
•
Code + #74 + access point
These entries allow a user to gain access to an access point.
•
Code + #75 + access point + function
The selectable functions available are Grant, Protect, Bypass. Selecting 'Grant" will
temporarily unlock a door. Selecting "Protect" will cause the door to unlock only when a
valid keypad entry is received. Selecting "Bypass" will cause the door to be permanently
unlocked to allow continuous access.
Programming the Keypad
Step
1
2
3
4
5
6
7
See Zone Programming in #93 Menu Mode Programming in the Programming Guide for a
detailed explanation.
14-6
PROM C
TRANSFORMER
Figure 14-2: Wiring the Vista Gateway Module
Action
Enter Zone Programming in the #93 Menu Mode.
Program the zone with a response type 27 (Access Point).
Enter the access point number (00-31) of the door and indicate whether this is an
entry or exit console.
Program whether this is an entry or exit point.
Enter the partition number.
Enter the input type as CS (09).
Enter the keypad ECP address.
}
ECHELON NETWORK
(PASSPOINT ACS)
4-PIN
KEYPAD
PLUG
GREEN
}
TO
BLACK
CONTROL'S
RED
KEYPAD
TERMINALS
YELLOW