ADEMCO VISTA-128B Installation And Setup Gude page 78

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

VISTA-128B Installation and Setup Guide
VistaKey Features
VistaKey features are as follows:
Each VistaKey communicates with the VISTA-128B via a special global polling protocol
of the V-Plex polling loop.
In the event local power to the VistaKey is lost, the VistaKey module provides back-up
monitoring of the Access Point door via a built-in V-Plex device that is powered solely
from the polling loop. It is programmed as a new type of V-Plex device as part of the
control's V-Plex Device Programming. A serial number label is affixed to the VistaKey
module for manual entry of its serial number.
The VistaKey supports up to 250 cardholders.
All configurable options for each VistaKey are accomplished via software, firmware, and
non-volatile memory, eliminating the need for PC board jumpers.
Access Point zone numbers (1-15) are assigned via a user-friendly, 16-position rotary
switch.
The addition and removal of VistaKey modules from the system is easily accomplished
via the VISTA-128B keypad.
Each VistaKey provides one open-collector output trigger (sink 12mA @ 12VDC).
Mounting and Wiring the VistaKey
To mount and wire the VistaKey module, perform the following steps:
Step
1
2
3
4
5
6
7
14-2
Action
Mount the VistaKey, Door Strike or Mag Lock, and Card Reader.
If applicable, mount the Door Status Monitor (DSM) and/or Request to Exit (RTE)
devices.
Using Figure 14-1 at the end of this section as a reference, connect the Card
Reader interface cable to TB3, making the +5v or +12v connection last.
Connect the leads to TB1 in the following order:
a. All ground leads to terminals 2, 5 and 9).
b. The (optional) DSM, RTE, and General Purpose leads to terminals 6, 7, and
8, respectively.
c.
Door Strike (or Mag Lock) lead to terminal 10.
d. Local +12v or +24v supply lead to terminal 1.
e. Local +12v or +24v supply lead to the N/C relay terminal 11 (if a Mag Lock is
being used), OR to the N/O relay terminal 10 (if a door strike is being used).
Connect the – polling loop and + polling loop leads (from the VISTA-128B) to
terminals 4 and 3 respectively.
Set the Address Select switch to the desired access door number (1-15).
Repeat steps 1 through 6 for each VistaKey being installed.