WIRED ZONE
EXPANSION
Nos. 4219 and 4229
if a No. 4219 Wired Expansion Module, or 4229 Wired Expansion/Relay Module is
Expansion
Modules
used, 8 wired EOLR zones can be added to the basic control's 2 zones, for a total
of 10.
Location
Can be mounted
within or outside of the Ademco
via30+ cabinet (see page 12).
Connections
Connects to the control's remote console terminals for
signaling.
Supervision
* Supervised against removal.
* Has tamper protection for security when mounted out-
side of the cabinet.
Zone
Information
|« Eight wired expansion
loops (designated A to H)
should be assigned zone numbers 10-17, and any or
all can be programmed individually (in field *56).
¢ if RF will be used in addition to one of these units (see
WIRELESS EXPANSION sections), any zone numbers
in the range of 18-63 (not 10-17) should be chosen for
the RF zones, even if some of the unit's wired ex-
pansion loops are not being used.
For example:
If only four of the wired expansion loops are being
used, a 4281H or 5881H RF Receiver could add 26 RF
zones (using any zone numbers in the range of 18-63)
to the system, for a combined total of 30 expansion
zones.
If a 4219 or 4229 is not being used, however, the same
receiver could add 30 RF expansion zones to the sys-
tem, assigned any zone numbers within a 10-63 range.
The
4219's
or 4229's
DIP
switch
must
be set
for a device
address
of "1", as described
in its
instructions (bottom 3 switches to the RIGHT..."on", and
the next switch above to the LEFT..."off").Switch
1
determines zone A's response time ("ON" = normal
response, "OFF" = fast response).
OFF <> ON
Settings
For additional information, see the instructions that accompany the 4219 and
4229.
=, =