ADEMCO VISTA-128B Installation And Setup Gude page 129

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

1*76 ACCESS RELAY # # (partition-specific)
The system can be programmed to provide user-activated access control. If enabled, the
assigned relay will pulse for 2 seconds when the user enters his code and presses 0.
Enter the relay number (00-96) for the relay that will be used for access control. Enter
00 if not used in this partition. This function has not been UL Listed for use with the
VISTA-128B control. Must be 00 for UL installations.
*Note: See the Access Control section for enhanced access control capability.
2*00 NUMBER OF PARTITIONS
Enter the number of partitions (1-8) to be used in the system.
2*01 DAYLIGHT SAVING TIME START/END MONTH
Enter the months (00-12) in which daylight savings time starts and ends.
Enter 00, 00 if daylight savings time does not apply to the user's region. Standard
setting for U.S. is 04,10.
2*02 DAYLIGHT SAVING TIME START/END WEEKEND
Enter the start and end weekends for daylight savings time as follows: 1=first;
2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard setting
for U.S. is 1,5.
U L
Fields 2*05 – 2*08 must be set to 0 for UL installations.
2*05 AUTO-ARM DELAY (partition-specific)
Enter the time between the end of the arming window and the start of auto arm
warning time in values of 01-14 times 4 minutes.
Enter 00 if no delay is desired.
Enter 15 if auto arming is not desired.
2*06 AUTO-ARM WARNING PERIOD (partition-specific)
Enter the time 01-15 in one-minute increments during which the user is warned by a
keypad sounding and display to exit the premises prior to auto arming of the system.
Enter 00 to disable the warning period.
2*07 AUTO-DISARM DELAY (partition-specific)
Enter the time between the end of the disarming window and the start of auto
disarming of the system in values of 01-14 times 4 minutes.
Enter 00 if no delay is desired.
Enter 15 if auto disarming is not desired.
2*08 FORCE ARM ENABLE (FOR AUTO-ARM) (partition-specific)
Enter 1 if the system should automatically bypass any faulted zones when it attempts to
auto arm. Otherwise enter 0.
Section 22 – Data Field Descriptions
[04,10]
|
[1,5]
[00]
|
[1]
|
[15]
|
[15]
|
[15]
|
[0]
22-15