VISTA-128B Installation and Setup Guide
Wireless Expansion
Supports up to 128 wireless zones using 5881 type RF receiver (fewer if using hardwire
and/or polling loop zones). Wireless zones have the following characteristics:
•
Supervised by control panel for check-in signals (except certain nonsupervised
transmitters)
•
Tamper protection for supervised transmitters
•
Individually assignable to one of 8 partitions
U L
Wireless devices may not be used in UL commercial burglary installations.
For specific information regarding number of wireless zones supported, see the section Wireless
Zone Expansion later in this manual.
System Zones
Provides zones for supervision of all peripheral devices (keypads, RF receivers, and relay
modules) and individual relays, as well as system zones (RF receivers and keypad panics).
Zone assignments are as follows:
(See the Zone Index/Zone Type Defaults section for a full explanation of these zones and
specific zone assignments.)
8 Partitions
Provides the ability to control 8 separate areas independently, each functioning as if it had
its own separate control. Partitioning features include:
•
A Common Lobby partition (1-8), which can be programmed to arm automatically when
the last partition that shares the common lobby is armed and to disarm when the first
partition that shares the common lobby is disarmed
•
A Master partition (9), used strictly to assign keypads for the purpose of viewing the
status of all 8 partitions at the same time (master keypads)
•
All zones assignable to one of 8 partitions
•
Keypads assignable to one of 8 partitions or to Master partition 9 to view system status
•
Ability to assign relays to one or all 8 partitions
•
Ability to display fire and/or burglary and panic and/or trouble conditions at all other
partitions' keypads (selectable option)
•
Certain system options selectable for each partition, such as entry/exit delay and
subscriber account number
1-2
Individual Relay Zones
Peripheral Device Zones
System Zones
601-632
800-831