1F – 400 ENGINE CONTROLS
EXHAUST GAS RECIRCULATION
VALVE (SOHC)
Removal Procedure
1. Disconnect the negative battery cable.
2. Disconnect the exhaust gas recirculation (EGR) valve
electrical connector.
3. Remove the bolts and the EGR valve.
Installation Procedure
1. Clean the cylinder head mating surface.
2. Install the new EGR valve gasket.
3. Install the EGR valve with the retaining bolts.
Tighten
Tighten the exhaust gas recirculation valve retaining
bolts to 20 NSm (15 lb-ft).
A402F069
4. Connect the EGR valve electrical connector.
5. Connect the negative battery cable.
DAEWOO T-154 BL2,3