The MCMS System Flags
Flag
ULTRA_SECURE_MODE
USE_GK_PREFIX_FOR_PSTN_CA
LLS
USER_LOCKOUT
USER_LOCKOUT_DURATION_IN_
MINUTES
USER_LOCKOUT_WINDOW_IN_MI
NUTES
V35_MULTIPLE_SERVICES
Polycom®, Inc.
Description
When set to YES enables the Ultra Secure Mode. When enabled,
affects the ranges and defaults of the System Flags that control:
•
Network Security
•
User Management
•
Strong Passwords
•
Login and Session Management
•
Cyclic File Systems alarms
Default: NO
For a list of flags affected when the Ultra Secure Mode is enabled,
see
System Flags affected by Ultra Secure
When set to YES the Gatekeeper Prefix is included in the DTMF
input string enabling PSTN participants to use the same input
string when connecting to an Collaboration Server whether the
Collaboration Server is a standalone MCU or part of a DMA
solution deployment.
Possible Values: YES / NO
Default: NO
For more information see
If YES, a user is locked out of the system after three consecutive
Login failures with same User Name. The user is disabled and
only the administrator can enable the user within the system.
Default: NO (in Ultra Secure Mode: YES)
For details, see
User Lockout
Defines the duration of the Lockout of the user.
Value: 0 - 480
0 means permanent User Lockout until the administrator
re-enables the user within the system.
Default: 0
Defines the time period during which the three consecutive Login
failures occur.
Value: 0 - 45000
0 means that three consecutive Login failures in any time period
will result in User Lockout.
Default: 60
Not Supported in RMX 1800.
If the connection of multiple Serial Gateways to RTM-LAN cards is
required:
The V35_MULTIPLE_SERVICES System Flag must be set to
YES.
The default value of the V35_MULTIPLE_SERVICES System Flag
is NO, enabling only one Serial Gateway to be supported per
RTM-LAN card.
System Configuration Flags
Mode.
PSTN Dial-in Using GK
Prefix.
Add?
803
Need help?
Do you have a question about the realpresence 1800 and is the answer not in the manual?