Bit Assignments For Error Field - Compaq AlphaServer ES45 Service Manual

Hide thumbs Also See for AlphaServer ES45:
Table of Contents

Advertisement

Model/Other
Optional data. For Compaq FRUs, the Compaq part alias
number (if one exists). For vendor FRUs, the year and
week of manufacture.
Alias/Misc
Miscellaneous information about the FRUs. For Compaq
FRUs, a model name, number, or the common name for the
entry in the Part # field. For vendor FRUs, the
manufacturer's name.
Table 4–3 lists bit assignments for failures that could potentially be listed in the
E (error) field of the show fru command. Because the E field is only two
characters wide, bits are "or'ed" together if the device has multiple errors. For
example, the E field for a FRU with both TDD (02) and SDD (04) errors would
be 06:
010 | 100 = 110 (6)
Table 4–3 Bit Assignments for Error Field
Bit Mask
(E Field)
Meaning
01
Hardware failure
02
TDD error has been logged
04
SDD error has been logged
08
Reserved
10
Checksum failure on bytes 0-62
20
Checksum failure on bytes 64-126
40
Checksum failure on bytes 128-254
80
FRU's system serial number does not match system's
SRM Console Diagnostics 4-61

Advertisement

Table of Contents
loading

Table of Contents