Compaq AlphaServer ES45 Service Manual page 255

Hide thumbs Also See for AlphaServer ES45:
Table of Contents

Advertisement

Sets the password that is prompted for at the beginning of a modem
session. The string cannot exceed 14 characters and is not case sensitive.
For security, the password is not echoed on the screen. When prompted for
verification, type the password again.
Sets the initialization string. The string is limited to 31 characters and
can be modified depending on the type of modem used. Because the
modem commands disallow mixed cases, the RMC automatically converts
all alphabetic characters entered in the init string to uppercase.
The RMC automatically configures the modem's flow control according to
the setting of the SRM com1_flow environment variable. The RMC also
enables the modem carrier detect feature to monitor the modem
connectivity.
Enables remote access to the RMC modem port by configuring the modem
with the setting stored in the initialization string.
Verifies the settings. Check that the Remote Access field is set to Enabled.
Dialing In
The following example shows the screen output when a modem connection is
established.
ATDT915085553333
RINGING
RINGING
CONNECT 9600/ARQ/V32/LAPM
RMC Password: *********
Welcome to RMC V1.2
P00>>> ^[^[rmc
RMC>
1. At the RMC> prompt, enter commands to monitor and control the remote
system.
2. When you have finished a modem session, enter the hangup command to
cleanly terminate the session and disconnect from the server.
Using the Remote Management Console
7-25

Advertisement

Table of Contents
loading

Table of Contents