Table 7–1 Status Command Fields
Field
On-Chip Firmware
Revision:
Flash Firmware
Revision:
Server Power:
System Halt:
RMC Power Control:
Escape Sequence:
Remote Access:
RMC Password:
Alert Enable:
Alert Pending:
Init String:
Dial String:
Alert String:
Com1_mode:
Last Alert:
Logout Timer:
User String:
Meaning
Revision of RMC firmware on the microcontroller.
Revision of RMC firmware in flash ROM.
ON = System is on.
OFF = System is off.
Asserted = System has been halted.
Deasserted = Halt has been released.
ON= System has powered on from RMC.
OFF = System has powered off from RMC.
Current escape sequence for access to RMC console.
Enabled = Modem for remote access is enabled.
Disabled = Modem for remote access is disabled.
Set = Password set for modem access.
Not set = No password set for modem access.
Enabled = Dial-out enabled for sending alerts.
Disabled = Dial-out disabled for sending alerts.
YES = Alert has been triggered.
NO = No alert has been triggered.
Initialization string that was set for modem.
Pager string to be dialed when an alert occurs.
Identifies the system that triggered the alert to the paging
service. Usually the phone number of the monitored system.
Identifies the current COM1 mode.
Type of alert (for example, power supply 1 failed).
The amount of time before the RMC terminates an inactive
modem connection. The default is 20 minutes.
Notes supplied by user.