Show Error Message Translation - Compaq AlphaServer ES45 Service Manual

Hide thumbs Also See for AlphaServer ES45:
Table of Contents

Advertisement

Table 4–2 Show Error Message Translation
Bit Mask
(E Field)
Text Message
01
<fruname> Hardware Failure
02
<fruname> TDD - Type:0 Test: 0
SubTest: Error: 0
04
<fruname> SDD - Type:0
LastLog: 0 Overwrite: 0
08
<fruname> EEPROM
Unreadable
10
<fruname> Bad checksum 0 to
64 EXP:01 RCV:02
20
<fruname> Bad checksum 64 to
126 EXP:01 RCV:02
40
<fruname> Bad checksum 128 to
254 EXP:01 RCV:02
80
<fruname> SYS_SERIAL_NUM
Mismatch
4-58
ES45 Service Guide
Meaning and Action
Module failure. FRUs that are known to
be connected but are unreadable are
considered hardware failures. An
example is power supplies.
Serious error. Run the Compaq Analyze
GUI, if necessary, to determine what
action to take. If you cannot run Compaq
Analyze, replace the module.
Serious error. Compaq Analyze (CA) has
written a FRU callout into the SDD area
and DPR global area. Follow the
instructions given by Compaq Analyze.
Reserved.
Informational. Use the clear_error
command to clear the error unless TDD
or SDD is also set.
Informational. Use the clear_error
command to clear the error unless TDD
or SDD is also set.
Informational. Use the clear_error
command to clear the error unless TDD
or SDD is also set.
Informational. Use the clear_error
command to clear the error unless TDD
or SDD is also set.

Advertisement

Table of Contents
loading

Table of Contents