Syntax
buildfru ( <fru_name> <part_num> <serial_num> [<misc> [<other>]]
or
-s <fru_name> <offset> <byte> [<byte>...] )
Arguments
<fru_name>
Console name for this FRU. This name reflects the position
of the FRU in the assembly hierarchy.
<part_num>
The FRU's 2-5-2.4 part number. This ASCII string should be
16 characters (extra characters are truncated). This field
should not contain any embedded spaces. If a space must be
inserted, enclose the entire argument string in double
quotes. This field contains the FRU revision, and in some
cases an embedded space is allowed between the part
number and the revision.
<serial_num>
The FRU's serial number. This ASCII string must be 10
characters (extra characters are truncated). The
manufacturing location and date are extracted from this
field.
<misc>
The FRU's model name or number or the common name for
the FRU. This ASCII string may be up to 10 characters
(extra characters are truncated). This field is optional,
unless <alias> is specified.
<other>
The FRU's Compaq alias number, if one exists. This ASCII
string may be up to 16 characters (extras are truncated).
This field is optional.
<offset>
The beginning byte offset (0–255 hex) within this FRU's
EEPROM, where the following supplied data bytes are to be
written.
<byte>...
The data bytes to be written. At least one data byte must be
supplied after the offset.
Options
-s
Writes raw data to the EEPROM. This option is typically
used to apply any FRU specific data.
SRM Console Diagnostics 4-9