Compaq AlphaServer ES45 Service Manual page 399

Hide thumbs Also See for AlphaServer ES45:
Table of Contents

Advertisement

Table D–16
DPR Locations A0:A9 (Continued)
DPR
Location
Description
A6
These bits indicate a door has been opened.
Bit 0
unused
1
CPU door is open
2
Fan door is open
3
PCI door is open
5
System CPU door is open
6
System fan door is open
7
System PCI door is open
A7
Temperature Warning Mask
Bit 0
CPU0 temp warning
1
CPU1 temp warning
2
CPU2 temp warning
3
CPU3 temp warning
4
Temp Zone 0 (LM78 0 on PCI backplane)
5
Temp Zone 1 (LM78 1 on PCI backplane)
6
Temp Zone 2 (LM78 2 on PCI backplane)
A8
Fan Controller Fault. This indicates a fan is not responding to a different
RPM range as set by the RMC. (It is used to indicate that the fan failed to
reach its maximum RPM at power-up.)
Bit 0
Fan 1
1
Fan 2
3
Fan 3
4
Fan 4
5
Fan 5
6
Fan 6
A9
These bits indicate which temperature zone the rise or fall in temperature
occurred in.
Bit 0
CPU fans spin at the maximum speed
Bit 1
CPU fans reduce the speed from the maximum speed
Bit 2
PCI fans spin at the maximum speed
Bit 3
PCI fans reduce the speed from the maximum speed
Registers
D-39