Console Data Log Event Environmental Error Logout Frame (680 Uncorrectable - Compaq AlphaServer ES45 Service Manual

Hide thumbs Also See for AlphaServer ES45:
Table of Contents

Advertisement

D.21 Console Data Log Event Environmental Error
Logout Frame (680 Uncorrectable)
Compaq Analyze uses the logout frame in Table D–20 for its
decomposition of all 680 system environmental uncorrectable error
frames.
Table D–20 Console Data Log Event Environmental Error Logout
Frame (680 Uncorrectable)
63
56 55
48 47
Revision (1)
Retryable/Second Error Flags
System Area Offet(0020)
Machine Check Frame Revision
Software Error Summary Flags
Cchip CPUx Device Interrupt Request Register (DIRx System Primary CPU
Environ_QW_1 (TIG System Management Information Register (SMIR))
Environ_QW_2 (TIG CPU Information Register (CPUIR))
Environ_QW_3 (TIG Power Supply Information Register (PSIR))
Environ_QW_4 (System_PS/Temp/Fan_Fault - LM78_ISR )
Environ_QW_5 (System_Doors)
Environ_QW_6(System_Temperature_Warning)
Environ_QW_7(System_Fan_Control_Fault)
Environ_QW_8(Fatal_Power_Down_Codes)
Environ_QW_9(Environmental Reserved 1)
NOTE: Only Environ_QW_8 contains valid error state capture. All other
Environ_QW_1-7, 9 will be zeroed.
1
Per Alpha SRM requirement.
40 39
32 31
24 23
Type (3)
Class (12)
Processor WHAMI
Frame Size 0070)
EV68 Area Offset(0020
Machine Check Code (206)
Fault Watcher)
16 15
8 7
0 Offset (Hex)
Length (80)
00000000
00000008
00000010
1
)
00000018
00000020
00000028
00000030
00000038
00000040
00000048
00000050
00000058
00000060
00000068
00000070
00000078
Registers
D-43

Advertisement

Table of Contents
loading