Table D–23 Bit Definition of Logout Frame Registers (Continued)
Register
Identification
Bit Field
<47>
<63:48>
System_Doors
<0>
<1>
(Environ_QW_5)
<2>
<3>
<4>
<5>
<6>
<7>
<63:8>
System_Tempera-
<0>
ture_Warning
<1>
<2>
(Environ_QW_6)
<3>
<4>
<5>
<6>
<63:7>
System_Fan_
<0>
Control_Fault
<1>
<2>
(Environ_QW_7)
<3>
<4>
<5>
<7:6>
<8>
<9>
<10>
<11>
D-56
ES45 Service Guide
Text Translation Description
Set = Power supply AC input high limit warning
Unused
Unused
Set = System CPU door is open
Set = System Fan door is open
Set = System PCI door is open
Unused
Set = System CPU door is closed
Set = System Fan door is closed
Set = System PCI door is closed
Unused
Set = CPU0 temperature warning fault has occurred
Set = CPU1 temperature warning fault has occurred
Set = CPU2 temperature warning fault has occurred
Set = CPU3 temperature warning fault has occurred
Set = System temperature zone 0 warning fault has
occurred
Set = System temperature zone 1 warning fault has
occurred
Set = System temperature zone 2 warning fault has
occurred
Unused
Set = System Fan 1 is not responding to RMC Commands
Set = System Fan 2 is not responding to RMC Commands
Set = System Fan 3 is not responding to RMC Commands
Set = System Fan 4 is not responding to RMC Commands
Set = System Fan 5 is not responding to RMC Commands
Set = System Fan 6 is not responding to RMC Commands
Unused
Set = CPU fans 5/6 at maximum speed
Set = CPU fans 5/6 reduced speed from maximum
Set = PCI fans 1-4 at maximum speed
Set = PCI fans 1-4 reduced speed from maximum.