3.4.5

SROM Error Messages

The SROM power-up identifies errors that may or may not prevent the
system from coming up to the console. It is possible that these errors
may prevent the system from successfully booting the operating
system. Errors encountered during SROM power-up are displayed on
the OCP.
Some errors are also displayed on the console terminal
screen if the console output is set to serial.
Table 3–4 lists the SROM error messages. The code numbers shown in the
Code column are displayed in place of OCP or SROM messages if the SROM
flash is invalid.
Table 3–4 SROM Error Messages
Code
SROM Message
FD
PCI data path error
FA
No usable memory detected
EF
Bcache data lines test error
EE
Bcache data march test error
ED
Bcache address test error
EC
CPU parity detection error
EB
CPU ECC detection error
EA
Bcache ECC data lines test error
E9
Bcache ECC data march test error
E8
Bcache TAG lines test error
E7
Bcache TAG march test error
E6
Console ROM checksum error
3-22
ES45 Service Guide
OCP Message
PCI Err
No Mem
BC Error
BC Error
BC Error
CPU Err
CPU Err
BC Error
BC Error
BC Error
BC Error
ROM Err