Compaq AlphaServer ES45 Service Manual page 398

Hide thumbs Also See for AlphaServer ES45:
Table of Contents

Advertisement

Table D–16
DPR Locations A0:A9 (Continued)
DPR
Location
Description
A2
If bit is set the associated fault is active.
Bit 0
CPU0_VCORE out of tolerance
1
CPU0_VIO out of tolerance
2
CPU1_VCORE out of tolerance
3
CPU1_VIO out of tolerance
4
PCI backplane LM78 1 is overtemp
5
Not used
6
Fan 4 fault
7
Fan 5 fault
A3
Bit 0
+1.5 volt out of tolerance
1
CPU0_VCACHE out of tolerance
2
CPU1_VCACHE out of tolerance
4
+2.5 volt out of tolerance
5
CPU2_VCACHE out of tolerance
6
CPU3_VCACHE out of tolerance
A4
If bit is set the associated fault is active.
Bit 0
CPU2_VCORE out of tolerance
1
CPU2_VIO out of tolerance
2
CPU3_VCORE out of tolerance
3
CPU3_VIO out of tolerance
4
PCI backplane LM78 2 is overtemp
5
Not used
6
Fan 3 fault
7
Fan 6 fault
A5
Bit 7
AC_input value high limit
Bit 6
AC_input value low limit
Bit 5
Monitor the temperature
Bit 4
Current from +12 volt rail is out of tolerance
Bit 3
Current from 5.5 volt rail is out of tolerance
Bit 2
Current from 3.3 volt rail is out of tolerance
Bit 1-0 Failing power supply number (0,1,2 are valid)
D-38