Compaq AlphaServer ES45 Service Manual page 68

Hide thumbs Also See for AlphaServer ES45:
Table of Contents

Advertisement

OpenVMS
Graphical Interface
Command-Line
Interface
NOTE:
A short IVP script is provided for a simple verification of device setup.
It is selectable from the GUI IVP menu, and the script is called
.Ivp_short.scp (ivp_short.vms). This script will run for 15 minutes
and then terminate with a Summary log. The short script may be run
prior to the long IVP script if desired, but not in place of the long IVP
script, which is the full IVP test.
The long IVP will run until the slowest device has completed one pass (typically
2 to 12 hours). This is called a Cycle of Testing.
2-16 ES45 Service Guide
1. From the Main Menu, select IVP, Load Script and
select Long IVP (the IVP tests will then load into the
Q-Vet process window).
2. Click the Start All button to begin IVP testing.
$ vet /int=char
Q-Vet_setup> execute ivp.vms
Q-Vet_setup> start
Note that commands are case sensitive.

Advertisement

Table of Contents
loading

Table of Contents