Interpreting Error Beep Codes; Reading The Console Event Log; Table 8-2: Error Beep Codes - Compaq AlphaServer 1000A Owner's Manual

Rackmount
Table of Contents

Advertisement

Troubleshooting Your System

Interpreting Error Beep Codes

Table 8–2 describes error beep codes you may encounter while using your system. For
example, if the serial read only memory (SROM) code could not find any good memory,
you would a 1-3-3 beep code (one beep, a pause, a burst of three beeps, a pause, and
another burst of three beeps).
Table 8–2: Error Beep Codes
Beep
Meaning
Code
1-1-2
A ROM data path error was
detected while loading ARC/SRM
console code.
1-1-4
The SROM code could not read the
Flash ROM headers, or there was a
checksum failure.
1-2-1
TOY NVRAM failure.
1-3-3
The SROM code could not find at
least 2 MB of good memory, or
there was no memory available.
3-1-2
The J1 jumper on the CPU card
was set incorrectly or the on-board
SCSI controller failed.
3-3-1
Generic system failure.
3-3-2
The J1 jumper on the CPU card
was set incorrectly or the PCI-to-
PCI controller failed.
3-3-3
Internal Qlogic controller failure.

Reading the Console Event Log

The system maintains a console event log consisting of status messages received during
startup testing. If problems occur during startup, standard error messages may be
embedded in the console event log. To display the console event log, use the cat el
command or, to display the log screen by screen, use the more el command.
8-4 AlphaServer 1000A Rackmount Owner's Guide
Action
Refer to the section, "Using the Fail-
Safe Loader."
Refer to the section, "Using the Fail-
Safe Loader."
Call your service representative.
Verify that the memory modules are
properly seated.
Replace faulty memory modules.
If replacement does not solve the
problem, call your service
representative.
Check that the J1 jumper is set at bank
1. (SeeFigure 9-8) If the jumper is
not the problem, call your service
representative.
Call your service representative.
Check that the J1 is set at bank 1.
(See Figure 9-8). If the jumper is not
the problem, Call your service
representative.
Call your service representative.

Advertisement

Table of Contents
loading