Mitsubishi Electric MELSEC iQ-R Series User Manual page 665

Programmable
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

3.
Set the transfer ranges between the link device and the CPU module device of the station for which a mode other than
cyclic synchronous mode is set.
Navigation window  "Parameter"  "Module Information"  Target module  [Module Parameter (Network)]  [Basic
Settings]  [Refresh Setting]
Select "Refresh Setting".
Set the start and end of the link device so that it is
compatible with the station to be used for the mode
other than the cyclic synchronous mode.
4.
To perform control in a mode other than the cyclic synchronous mode, operate the link device corresponding to each
object.
Downloaded from
ManualsNet.com
search engine
Set the transfer destination of
the link device. The W device
is specified in this example.
Set the start of the transfer destination of the link device.
In this example, the transfer is set to W10 to W1F for RWr and
W27 to W3E for RWw.
When finished setting the network configuration
settings and refresh settings, click "Apply".
Appendix 3 Devices Compatible with CC-Link IE TSN
A
APPX
663