Error code
(Hexadecimal)
1B27H
1B28H
1B29H
1B2AH
1B2BH
1B2CH
1B2DH
1B2EH
1B2FH
1B30H
14 TROUBLESHOOTING
634
14.5 List of Error Codes
Downloaded from
ManualsNet.com
Error name
Error details and causes
Sub point setting error
Start point is equal to sub point in the circular
interpolation or helical interpolation with sub points
designated.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Sub point setting error
End point is equal to sub point in the circular
interpolation or helical interpolation with sub points
designated.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Sub point setting error
Start point, end point, and sub point are in line with
each other in the circular interpolation or helical
interpolation with sub points designated.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Sub point setting error
Sub point address is outside the range of -2147483648
to 2147483647 in the circular interpolation or helical
interpolation with sub points designated.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
End point setting error
Start point is equal to end point in the circular
interpolation or helical interpolation with sub points
designated.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
End point setting error
End point address is outside the range of -2147483648
to 2147483647 in the circular interpolation or helical
interpolation with auxiliary point designation and center
point designation.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Center point setting error
Start point is equal to center point in the circular
interpolation or helical interpolation with center point
designation.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Center point setting error
End point is equal to center point in the circular
interpolation or helical interpolation with center point
designation.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Center point setting error
Center point address is outside the range of -
2147483648 to 2147483647 in the circular
interpolation or helical interpolation with center point
designation.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Outside address range
In the speed-position switching control and the
position-speed switching control, the setting value of a
positioning address is negative.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops with the setting
(deceleration stop/rapid stop) of the detailed parameter
2 Rapid stop selection (stop group 3). (Note that the
deceleration stop only occurs during the manual pulse
generator operation.)
search engine
Remedy
Correct the sub address (arc address).
Correct the sub address (arc address).
Correct the sub address (arc address).
Correct the sub address (arc address).
Correct the end address (positioning address)
Correct the end address (positioning address)
Correct the center point address (arc address)
Correct the center point address (arc address)
Correct the center point address (arc address)
Correct the positioning address.