[Md.39] In speed limit flag
Stores whether the in speed limit is in progress or not.
Storage value
0
1
• If the speed exceeds "[Pr.8] Speed limit value" ("[Pr.31] JOG speed limit value" at JOG operation control) due to a speed
change or override, the speed limit functions, and the in speed limit flag turns ON.
• When the speed drops to less than "[Pr.8] Speed limit value" ("[Pr.31] JOG speed limit value" at JOG operation control), or
when the axis stops, the in speed limit flag turns OFF.
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.40] In speed change processing flag
Stores whether the in speed change is in progress or not.
Storage value
0
1
• The speed change process flag turns ON when the speed is changed during positioning control.
• After the speed change process is completed or when deceleration starts with the stop signal during the speed change
process, the in speed change process flag turns OFF.
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.41] Special start repetition counter
• This area stores the remaining number of repetitions during "repetitions" specific to special starting.
• The value stored is 0 to 255.
• The count is decremented by one (-1) at the loop end.
• The control comes out of the loop when the count reaches "0".
• This area stores "0" within an infinite loop.
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.42] Control system repetition counter
• This area stores the remaining number of repetitions during "repetitions" specific to control system.
• The value stored is 0000H to FFFFH.
• The count is decremented by one (-1) at the loop start.
• The loop is terminated with the positioning data of the control method "LEND", after the counter becomes "0".
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
Downloaded from
ManualsNet.com
In speed limit flag
Not in speed limit (OFF)
In speed limit (ON)
Speed change flag
Not in speed change (OFF)
In speed change (ON)
search engine
12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data