[Cd.55] Input value for manual pulse generator via CPU
• Set the values used as the input values for the manual pulse generator via the high-speed counter module in order.
• Refer to the manual of the high-speed counter module for the input method.
MELSEC iQ-R High-Speed Counter Module User's Manual (Startup)
MELSEC iQ-R High-Speed Counter Module User's Manual (Application)
Fetch cycle: 8.0 [ms]
• Although "[Cd.55] Input value for manual pulse generator via CPU" is fetched every 8.0 ms, synchronization with the scan
time of the CPU module is not performed, so the speed change of the axis may become large if the refresh cycle of "[Cd.55]
Input value for manual pulse generator via CPU" is slow. Use the following methods to smooth the speed change.
• Refresh "[Cd.55] Input value for manual pulse generator via CPU" in a cycle that is 8.0 ms or less.
• Smooth the speed change by using the smoothing function of "[Pr.156] Manual pulse generator smoothing time constant".
• When executing manual pulse generator operation using "[Cd.55] Input value for manual pulse generator via CPU", set the
following items as shown below in [Module Parameter]  [Basic Settings] of the high-speed counter module.
Setting item
Pulse input mode
Counting speed setting
Counter type
Counter operation mode
Preset value setting
Coincidence output point No.1
Coincidence output point No.2
Ring counter upper limit value
Ring counter lower limit value
Set the movement amount per fetch cycle in "[Cd.55] Input value for manual pulse generator via CPU" within
the range of -2147483648 to 2147483647. When a value outside the range is set , the movement amount of
the manual pulse generator and the movement amount of the output value may not match.
■Setting range
• Set with a decimal.
Setting range of [Cd.55] (Unit)
-2147483648 to 2147483647 (pulse)
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 System control data
■Default value
Set to "0".
Downloaded from
ManualsNet.com
search engine
Setting value
Set according to the system.
Set according to the system.
Linear counter
Pulse count mode
0
0
0
Set according to the system.
Set according to the system.
12 DATA USED FOR POSITIONING CONTROL
12
517
12.8 Control Data