[Da.10] M code/Condition data No./No. of LOOP to LEND repetitions/No. of pitches
Set an "M code", a "condition data No.", the "Number of LOOP to LEND repetitions" or the "Number of pitches" depending on
how "[Da.2] Control method" is set.
*1 The condition data specifies the condition for the JUMP instruction to be executed. (A JUMP will take place when the condition is
satisfied.)
■If a method other than "JUMP instruction", "LOOP", and "3-axis helical interpolation control"
is selected as "[Da.2] Control method"
Set an "M code".
If no "M code" needs to be output, set "0" (default value).
■If "JUMP instruction" or "LOOP" is selected as "[Da.2] Control method"
Set the "condition data No." for JUMP.
• 0: Unconditional JUMP to the positioning data specified by "[Da.9] Dwell time/JUMP destination positioning data No.".
• 1 to 10: JUMP performed according to the condition data No. specified (a number between 1 and 10). Make sure that you
specify the number of LOOP to LEND repetitions by a number other than "0". The error "Control method LOOP setting
error" (error code: 1B33H) will occur if you specify "0".
■If "3-axis helical interpolation control" is selected as "[Da.2] Control method"
Set the number of pitches for the linear interpolation axis. The rotation speed of the circular interpolation is set with the
number of pitch.
[Da.2] setting value
JUMP instruction: 82H
Helical interpolation: 20H to 25H
LOOP: 83H
Other than the above
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 404 Positioning data
12 DATA USED FOR POSITIONING CONTROL
466
12.4 Positioning data
Downloaded from
ManualsNet.com
*1
Setting item
Condition data No.
Number of pitches
Repetition count
M code
search engine
Value set with the engineering tool
0 to 10
0 to 999
1 to 65535
0 to 65535
Value set with a program
0 to 10
0 to 999
1 to 65535
0 to 65535