[Md.29] Speed-position switching control positioning movement amount
The movement amount for the position control to end after changing to position control with the speed-position switching
control is stored. When the control method is "Reverse run: position/speed", the negative value is stored.
As shown in the diagram below, the hexadecimal monitor value is changed to a decimal integer value. The decimal integer
value can be converted into other units by multiplying said value by the following conversion values.
Monitor value
E
A
(High-order buffer memory) (Low-order buffer memory)
A
B
C
Decimal integer value
Unit
m
inch
degree
pulse
Refresh cycle: Immediate
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.30] External input signal
The ON/OFF state of the external input signal is stored.
Buffer memory configuration
b15
b14
b13
b12
0
0
0
*1 This area stores the states of the external input of servo amplifier or buffer memory of the Motion module set by "[Pr.116] FLS signal
selection", "[Pr.117] RLS signal selection", "[Pr.118] DOG signal selection", and "[Pr.119] STOP signal selection".
Refresh cycle: Operation cycle
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
12 DATA USED FOR POSITIONING CONTROL
492
12.7 Monitor Data
Downloaded from
ManualsNet.com
Low-order buffer memory
b15
F
G
H
High-order buffer memory
b31
B
C
D
Sorting
D
E
F
G
H
Converted from hexadecimal to decimal
Conversion value
-1
10
-5
10
-5
10
0
10
b11
b10
b9
b8
b7
b6
0
0
0
0
0
0
(5)
Not used
Not used
search engine
b12
b8
b4
E
F
H
G
b28
b24
b20
A
B
C
D
b5
b4
b3
b2
b1
b0
0
0
(4)
(3)
(2)
(1)
Not used
b0
b16
Stored items
*1
(1)
Lower limit signal
*1
(2)
Upper limit signal
*1
(3)
Stop signal
(4)
External command signal/
switching signal
*1
(5)
Proximity dog signal
Storage
value
0: OFF
1: ON