Toro Greensmaster eFlex 1800 Service Manual page 81

Hide thumbs Also See for Greensmaster eFlex 1800:
Table of Contents

Advertisement

Removing the Transmission Drive Belt
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E
1. Park the machine on a level surface, turn the key switch to the O
and remove the key from the key switch. Disconnect the battery pack; refer
to
Connecting the Lithium Battery Pack (page
2. Remove the battery pack from the machine; refer to
Battery Pack (page
3. Use the tips of needle nose pliers to spread the ends of the driveshaft wire
(item 6 in
Figure
43) in the telescoping coupler. With the wire ends spread,
slide the coupler from the transmission shaft.
During disassembly, ensure that tension is released from the
transmission belt before removing the transmission cover.
4. Rotate the engage/disengage shaft clockwise to remove tension on the
transmission belt; refer to
5. Remove the 7 washer-head screws (item 3 in
transmission cover to the transmission. Carefully remove the cover from the
transmission. Remove and discard the gasket.
6. Ensure that the wave washers (item 2 in
bores of the transmission cover.
g204326
1.
Engage/disengage shaft
2.
Drive pulley
7. For assembly purposes, note the transmission belt routing
8. Remove the transmission belt from the drive and idler pulleys in the
transmission.
9. Check the condition of all the pulleys and idler components.
10. Clean the inside of the transmission before installing new belt.
5–74).
IMPORTANT
Transmission Belt Tensioner (page
Figure
Figure 44
3.
Idler pulley
4.
Drum drive pulley
Page 4–39
Traction and Reel Drive System: Service and Repairs
position,
FF
4–3).
Removing the Lithium
4–5).
Figure
43) that secure the
43) remain in the bearing
5.
Reel clutch pulley
6.
Idler pulley
(Figure
44).