Testing the Main Contactor (continued)
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E
7. If testing determines that the main contactor is damaged, ensure that the
battery pack is disconnected and then replace the main contactor.
8. After you complete the main contactor testing, install the power center cover
to the machine
(Figure
the battery cover and secure with 8 bolts (for Models 04042, 04043, 04046
and 04049 fitted with 04069).
9. Connect the battery pack; refer to
(page
5–7).
112) (for models 04042, 04043 and 04046) and install
Connecting the Lithium Battery Pack
Page 5–65
Electrical System: Testing the Electrical Components