Toro Greensmaster eFlex 1800 Service Manual page 263

Hide thumbs Also See for Greensmaster eFlex 1800:
Table of Contents

Advertisement

Removing the Grooming Reel (Counter Rotating Groomer Drive) (continued)
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E
3. Remove the cutting unit from the machine and place cutting unit on a flat
work area.
4. Ensure that the handle on groomer cover is rotated toward front of machine
so that the groomer drive is engaged.
5. Remove groomer cover assembly (item 22 in
machine; refer to
Groomer Cover (Counter Rotating Groomer Drive) (page
8–7). Discard gasket.
g228291
1.
Extension spring
2.
43T idler gear
6. Carefully remove extension spring from anchor points on right drive plate
(Figure
193).
g228292
1.
Right drive plate assembly
2.
Flange nut
7. Remove the 2 idler gears (43T and 47T) from the right drive plate assembly
(Figure
194). The bearings are pressed into the gears.
8. Loosen 2 bolts (item 7 in
arms.
Figure 193
3.
47T idler gear
4.
Groomer drive gear
Figure 194
3.
43T gear/bearing
4.
47T gear/bearing
Figure
192) that secure front roller shaft to groomer
Page 8–15
Figure
192) and gasket from
Belt Driven Groomer: Service and Repairs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster eflex 2100Greensmaster eflex 2120

Table of Contents