ZyXEL Communications ZyWall ATP series User Manual page 792

Table of Contents

Advertisement

The following table describes the labels in this screen.
Table 354 Maintenance > Diagnostics > Wireless Frame Capture > Capture
LABEL
MON Mode APs
Configure AP to
MON Mode
Available MON
Mode APs
Capture MON Mode
APs
Misc Setting
File Size
File Prefix
Capture
Stop
Reset
Chapter 40 Diagnostics
DESCRIPTION
Click this to go the Configuration > Wireless > AP Management screen, where you can
set one or more APs to monitor mode.
This column displays which APs on your wireless network are currently configured for
monitor mode.
Use the arrow buttons to move APs off this list and onto the Captured MON Mode APs
list.
This column displays the monitor-mode configured APs selected to for wireless frame
capture.
Specify a maximum size limit in kilobytes for the total combined size of all the capture
files on the Zyxel Device, including any existing capture files and any new capture files
you generate.
Note: If you have existing capture files you may need to set this size larger or
delete existing capture files.
The valid range is 1 to 50000. The Zyxel Device stops the capture and generates the
capture file when either the file reaches this size.
Specify text to add to the front of the file name in order to help you identify frame
capture files.
You can modify the prefix to also create new frame capture files each time you perform
a frame capture operation. Doing this does no overwrite existing frame capture files.
The file format is: [file prefix].cap. For example, "monitor.cap".
Click this button to have the Zyxel Device capture frames according to the settings
configured in this screen.
You can configure the Zyxel Device while a frame capture is in progress although you
cannot modify the frame capture settings.
The Zyxel Device's throughput or performance may be affected while a frame capture
is in progress.
After the Zyxel Device finishes the capture it saves a combined capture file for all APs.
The total number of frame capture files that you can save depends on the file sizes and
the available flash storage space. Once the flash storage space is full, adding more
frame captures will fail.
Click this button to stop a currently running frame capture and generate a combined
capture file for all APs.
Click this button to return the screen to its last-saved settings.
ZyWALL ATP Series User's Guide
792

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Atp500Atp200Atp800

Table of Contents