Setting Filters - Omron ZW-XC7 User Manual

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Setting Filters

Set the filter condition when filtering information obtained from the sensor before output.
The following types of filters can be set depending on purpose.
Displacement
Waveform when
Smooth
filter is not set
Median filter
[MEDIAN]
Average filter
[AVE]
Displacement
Differ filter
0
[DIFFER]
Waveform when
filter is not set
Frequency filter
[FREQ]
Three frequency variations
are mixed.
ZW-7000 User's Manual
Spike-like changes are
removed.
Changes are smoothed
out.
Changes are extracted to
eliminate displacement value.
Lowpass filter [LOPASS]
Sudden changes are removed.
Highpass filter [HIPASS]
Gradual changes are removed.
Bandpass filter [BDPASS]
A given change is detected.
Setting the Output Conditions
115

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-7000 series

Table of Contents