Setting Communications Specifications (Rs-232C Communications) - Omron ZW-C1*T User Manual

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

Setting Communications Specifications (RS-232C Communications)

Setting RS-232C communications on the sensor body
Set RS-232C communications on the displacement sensor body.
 Explorer pane
 Edit pane
Item
Description
Baud rate
Sets the data transfer speed.
Data length
Sets the data length.
Parity
Sets the parity bit (error detection sign).
Stop bit
Sets the stop bit.
Delimiter
Sets the delimiter (data delimiter).
CS/RS
Sets the flow control.
Note
• With the ZW series, communication cannot be established under the following condition.
Data length: 7-bit and Parity: None
• The RS-232C communication specifications can also be set with key operations on the Sensor Controller.
9-13 Connecting by No-protocol Communications p.277
ZW User's Manual
: [Device Group] | [(Sensor Name)] | [System] |
[System Data] (double-click)
: [RS-232C Communications Settings] icon (
)
Range
9600bps, 19200bps, 38400bps (default value),
57600bps, 115200bps
8 bits (default value), 7 bits
None (default value), odd, even
1bit (default), 2bit
CR (default), LF, CR+LF
OFF(default value)/ON
No-protocol Connection