Minimum PDO Communications Cycle Time
Do not set the communication cycle (PDO communication cycle time) for EtherCAT communication to a value
lower than the applicable minimum time given in the following table.
The minimum communication cycle (PDO communication cycle time) depends on the Data output byte size and
the use of the User area differs with the Number of controlled lines, as shown below. When multi-line random
trigger mode is used, the minimum communication cycle is the minimum value of the maximum byte size for each
line.
If the Communication cycle (PDO Communication cycle time) is set lower than the minimum value below, an
exception (AL status code: 0x0035) will occur and EtherCAT communications will be lost.
• Do not use the User area:
Number of controlled
lines
1 line
2 lines
3 lines
4 lines
5 lines
6 lines
7 lines
8 lines
• Use the User area
Number of controlled
lines
1 line
2 line
3 line
4 line
5 line
6 line
7 line
8 line
58
EtherCAT Connections (FH-1000 series/FH-3000 series only)
Data output byte size
32 bytes
64 bytes
125 μs
250 μs
500 μs
500 μs
500 μs
1,000 μs
Data output byte size
32 bytes
64 bytes
125 μs
250 μs
500 μs
500 μs
1,000 μs
1,000 μs
1,000 μs
128 bytes
250 μs
500 μs
500 μs
1,000 μs
1,000 μs
128 bytes
250 μs
500 μs
1,000 μs
Not supported.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
256 bytes
250 μs
1,000 μs
Not supported.
Not supported.
Not supported.
256 bytes
500 μs
1,000 μs
Not supported.
Not supported.
Not supported.