Changing processing unit parameters
The set parameters for the processing units set in the scene currently being used are changed.
<Command format>
<Response format>
When processing is performed normally
When processing is not performed normally
<Parameters explanation>
Processing unit No.
Specifies the processing unit number (0 to the number of unit items −1).
External reference table
Varies depending on the specified processing unit processing items. For more details, refer to
No.
External Reference Table for each processing item in Processing Item List Manual.
Setting Data
Sets the value of the settings data.
(Example)
When "Skipping angle" (external reference table value "124") in [Search] set as the 6th processing unit
(processing unit number "5") is changed to "10"
<Command>
<Response>
(Example)
When "Verification string" (external reference table value "139") in [Character Inspection] set as the 7th
processing unit (processing unit number "6") is changed to "ABC"
<Command>
U N I T D A T A
6
<Response>
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
C
1 3 9
A B C