Omron FH series User Manual page 264

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Example 2: Outputting Data with More Than One Output Unit without Handshaking
Command Code
Command Parameter
Command
Area
Command Execute
Response
Command Completion
Area
Data Output
Area
1
The measurement command code and command parameters are set from the PLC.
2
Next, confirm that the BUSY signal and the Command Completion (FLG) signal have
turned OFF and then turn ON the Command Request (EXE) signal again. A request is
sent to the Sensor Controller.
3
The Sensor Controller executes measurement processing and turns ON the BUSY
signal when the request is received.
4
When the first Fieldbus Data Output Unit in the measurement flow is executed, the
Sensor Controller outputs the output data for the first Fieldbus Data Output Unit to the
Data Output Area.
5
The Sensor Controller turns ON the Result Completion (GATE) signal when it has
output the output data to the Data Output Area.
6
The Sensor Controller turns OFF the Result Completion (GATE) signal after the output
time set in the EtherNet/IP settings has elapsed.
7
The second Fieldbus Data Output Unit in the measurement flow is executed.
8
When the time that is set for the output period in the EtherNet/IP settings has elapsed,
the Sensor Controller outputs the output data for the second Fieldbus Data Output Unit
to the Data Output Area.
The data for the first Fieldbus Data Output Unit is overwritten at that time.
9
The Sensor Controller turns ON the Result Completion (GATE) signal and then turns it
OFF after the output time that is set in the EtherNet/IP settings has elapsed.
262
Communicating with EtherNet/IP
ON
OFF
ON
OFF
ON
(EXE) signal
OFF
ON
Busy
(BUSY) signal
OFF
ON
(FLG) signal
OFF
Data Output
ON
Completion
OFF
(GATE) signal
ON
Output Data
(DATA)
OFF
(1)
(2)
*1: A timeout error will occur if you do not turn off the Command Execution (EXE) signal from Sensor Control-
ler (master) within 10 seconds. Then Command Completion (FLG) signal and Busy (BUSY) signal will be
forced to turn off.
*2: Busy (BUSY) signal is automatically switched ON to OFF when the command execution is completed.
Measurement command
Measurement command is running.
(3)
(8)
(6)
First data output
(5)
(4) First Fieldbus Data
Output Unit is executed.
Vision System FH/FZ5 Series User's Manual
(11)
*1
*2
(12)
(9)
Second data output
This data is overwritten by the
(8)
(10)
second data output.
(7) Second Fieldbus Data
Output Unit is executed.
for Communications Settings (Z342)