• The following series with 4 or 8 camera inputs has two Ethernet ports:
• FH-1000 series
• FH-3000 series
Set the settings for the two Ethernet ports as follows:
• Communications Module settings
Use the same setting for both ports.
• IP address settings
Set a different IP address for each Ethernet port.
The IP address for the top Ethernet port is set in [Address setting], and the IP address for the bottom Ethernet port is
set in [Address setting 2]. Note that the top Ethernet port on the FH does not support EtherNet/IP communication. By
using both Ethernet ports simultaneously, you can use the bottom port for PLC Link, non-procedure, Ethernet, or IP
communications with a PLC and the top port for FTP or remote operation communications with an external device.
• The following Sensor Controller type has one Ethernet port:
FH-L series
FH-1000/FH-3000 series with two camera inputs
In this case, the IP address of the Ethernet port is set in [Address setting 2].
• The FZ5 has only one Ethernet port.
In this case, the IP address of the Ethernet port is set in the [Address setting].
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Communicating with EtherNet/IP
2
223