Omron FH series User Manual page 313

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Note
The overall judgement gives the results of more than one processing item. As a result, the overall judgement will be NG
if even one of the individual judgement results is NG.
Individual judgement results
Processing unit 0
OK
Processing unit 1
NG
Processing unit n
OK
Parallel Data Output
The measured values of processing items or the calculation results of expressions are output.
Data items can be set from data 0 to data 7. Each item is output using the 16 bits from DO0 to DO15.
The data output specifications are as follows:
• Only integers are output. Decimals are rounded off.
• The range of values that can be output is as follows:
Binary format: −32768 to +32767
BCD format: −999 to +999
If the measurement value is out of range, the actual measurement value is not output and the minimum or
maximum value of the range is output instead.
Data type
Binary
BCD
Note
When the operation mode is set to Multi-line Random-trigger Mode, the parallel data output range is between -127 and
127 for binary data, and -9 and 9 for BCD data.
Parallel Judgement Output
The measured values of the processing items or calculation results are judged and the judgement results are
output.
Judgement results can be set from judgement 0 to judgement 15. Each result is output with 16 bits from DO0
to DO15.
Setting Up Parallel Data Output
The measured values of processing items or the calculation results of expressions are output.
Registering Parallel Output Units
Register the processing items for parallel data output in the measurement flow.
1
Click [Edit flow] in Toolbar.
2
Select the [Parallel Data Output] processing item from the processing item tree.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Overall judgement result
NG (OR signal: ON)
If there is even one NG judgement,
the overall judgement will be NG
and the output will be turned ON.
Measurement value that is below the
possible output range
A value of −32768 is output.
A value of −999 is output.
Measurement value that is above the
possible output range
A value of +32767 is output.
A value of +999 is output.
Parallel Communications