REGIMAGE or RID
Registers specified image data as registered image
Registers the data of a specified image as a registered image. The status after the command is executed is the
same as after the operation is executed for the Register Button in the Registered Image Manager. If the source
to register is 0, the last measured image, command argument 3, can be omitted.
<Command format>
R E G I M A G E
or
R I D
<Response format>
When processing is performed normally
When processing is not performed normally
<Parameters explanation>
Registered image number Specifies the registered image number: 0 to 999.
0: Last measured image
Source to register
1: System logging image
2: Image file
If you have specified a system logging image as the source to register, specify a logging image
Logging image number/
number: 0 to the number of the logging system images −1.
File name
If you have specified an image file, specify a file name with 0 to 256 characters.
(Example)
When an image with registered image number "100" and logging image number "10" is registered
<Command>
<Response>
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
C
R
Logging image number/File name (256 characters max.)
Source to register (1 digit)
Registered image number (3 digits max.)
C
R
Logging image number/File name (256 characters max.)
Source to register (1 digit)
Registered image number (3 digits max.)
3
495
Command Control