Connection Settings
Originator device (PLC)
Target device (Sensor
Controller)
Packet interval (RPI)
Timeout value
*1:
PLC tags and tag sets need to be same.
*2:
Adjust this value based on the communications settings of the Sensor Controller (i.e., the output period and the output
time). Reference:
IMPORTANT
• If I/O memory addresses are specified for the communications areas, the information in the communications areas
will be cleared when the operating mode of the PLC changes unless addresses in the CIO Area, which are
maintained, are specified.
• The following assembly object is required to specify instances when the EDS file is not used.
230
Communicating with EtherNet/IP
Parameter
Input tag set
Connection type
Output tag set
Output tag set
Input tag set
EtherNet/IP Communications Cycle (RPI) (p.215)
PLC_tag_set_name-[48Byte]
Any (default: Point to Point connection)
PLC_tag_set_name-[20Byte]
*1
Input_101-[48Byte]
*1
Output_100-[20Byte]
*2
Any (default: 50.0)
User specified (default: Packet interval (RPI) × 4)
Set the timeout interval so that it is longer than the Sensor's measure-
ment processing time.
Vision System FH/FZ5 Series User's Manual
Setting
*1
*1
for Communications Settings (Z342)