RS-232C/422 Communications
Before Performing a Communications Test
This example assumes that [Serial (RS-232C/422)] − [PLC Link (SYSMAC CS/CJ/CP/One)] is selected as
the Communications Module.
Stop the program on the PLC when you check the communications settings.
Checking the Communications Settings
Use the following procedure to check if the communications settings are correct.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
1. On the Main Window, select [Tool]
− [System Settings]. Select
[System data] from the tree on the
left, and then select
[Communication] − [RS-232C/422
(PLC Link (SYSMAC
CS/CJ/CP/One))].
2. Set these settings based on the
communications specifications.
3. Click the [PLC Link settings] tab.
4. Set the area settings.Set these
settings based on the connected
PLC.
5. Set the output control.
Set whether to provide an interlock
with the PLC when performing data
output.
6. This completes the Sensor Control-
ler settings.
Communicating with PLC Link
2
191