Omron FH series User Manual page 105

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Event name
Change in Connected Camera
Meaning
The Camera that is connected is different from when data was last saved.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
EtherCAT NET RUN
Indicators
Variable
System-defined
variables
None
Assumed cause
The Camera connection information in
Cause and
the scene data does not agree with the
correction
connection information for the Cam-
era connected to the Controller.
Attached
None
information
Precautions/
This error will occur if you load system and scene group 0 data (bkd file) that was edited with simulation software to the
Remarks
Controller. Save the data to the Controller and restart the Controller.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
Correction
Connect a Camera that agrees with
the Camera connection information in
the scene data or edit the scene data
according to the connection informa-
tion for the Camera connected to the
Controller.
EtherCAT Connections (FH-1000 series/FH-3000 series only)
Event code
385A 0000 hex
Slave
Detection timing
Error reset (after
resetting the error
Log category
in the slave)
The Camera image can be input, but an unintentional num-
ber of Camera pixels, color, or monochrome information
may be measured.
EtherCAT LINK/ACT
---
Name
---
Prevention
Make sure that the Camera connection
information in the scene data agrees
with the connection information for the
Camera connected to the Controller.
After turning ON
slave power
System
2
---
---
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents