• When the [ASCII] Output Format Is Selected
When [ASCII] is set as the output format, set the following format settings.
When [Binary] is set as the output format, no settings are needed.
Setting item
Digits of integer
Digits of decimal
Minus
Plus
0 suppress
Field separator
Record separator
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Set value [Factory default]
0 to [10]
0 to [4]
• [−]
• 8
• [none]
• +
• Available
• [OFF]
• OFF
• [Comma]
• Tab
• Space
• Delimiter
• OFF
• Comma
• Tab
• Space
• [Delimiter]
Description
Specify the digits of the integer part including the sign. For
positive numbers, the plus sign is not output.
Example:
Setting: 4 digits, Data: −5619
"−999" would be output.
Specify the number of output digits in the decimal part. Lower
decimal digits are rounded up before the data is output.
When 0 is selected, the decimal digits will be rounded off.
Select what is displayed in the sign digit for a negative num-
ber.
Select what is displayed in the sign digit for a positive num-
ber.
Select the method for adjusting when there is a blank to the
left of the output data.
Available: Insert 0 into the blank digits.
OFF: Insert a space for unused character.
Example: If the integer section is set to 5 digits and the deci-
mal section is set to 3 digits, the data is 100.000
Available: 00100.000
OFF: _100.000 (_ represents a space)
Select the separator for output data.
*1:
The delimiter is obtained from the system.
Select the separator for each time data is output.
*1:
The delimiter is obtained from the system.
Non-procedure Communications