• Output Signals
Signal
BUSY
READY
ACK (FH only)
Note
When the input command is not received correctly, the ERROR signal turns ON.
IMPORTANT
Do not change the scene group during parallel continuous measurement or when the STEP signal is being input
continuously. If you must change the scene group at one of these times, set [Unchecked] in [Save scene group on
scene switch] in either of the settings items below.
Refer to
Changing the Scene or Scene Group in the Vision System FH/FZ5 Series User's Manual (Cat. No.
Z365).
Refer to
Setting the Conditions That Are Related to Operation during Measurement in the Vision System FH/FZ5
Series User's Manual (Cat. No. Z365).
• Input Signals (Scene/Scene Group Switching)
Signal
DI0 to DI4
DI5
DI6
DI7
Note
The amount of time during which the BUSY signal is turned ON when a scene is switched can be changed.
Select [Measurement setting] from the [Measure] menu and make the setting in the conditions related to operation
during measurement.
Refer to
Setting the Conditions That Are Related to Operation during Measurement in the Vision System FH/FZ5
Series User's Manual (Cat. No. Z365).
342
Parallel Communications
Indicates that the Controller is currently switching the scene or scene group.
Do not input next command while the BUSY signal is ON. Otherwise, on-going processing or com-
mands that are input will not be performed correctly.
Turns OFF while a scene or a scene group is being switched. Turns OFF as long as the BUSY sig-
nal is ON.
Turn ON when execution of the DI command is completed.
Set the scene number (0 to 31).
When a DI terminal offset is set, the set offset is added.
ON
Select Scene: OFF
Set Scene Group: ON
This is the execution trigger.
After DI0 to DI6 are set, turn ON DI7 after an interval over 1 ms.
The BUSY signal is ON during command execution. After checking that the BUSY signal has
turned ON, turn DI7 OFF, and then turn DI0 to DI6 OFF. If the DI7 signal OFF timing cannot be set
faster than the BUSY signal OFF timing on the control side, set the scene switching additional time
to lengthen the BUSY signal OFF timing.
Refer to
Setting the Conditions That Are Related to Operation during Measurement in the Vision
System FH/FZ5 Series User's Manual (Cat. No. Z365).
Description
Description
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents