Clear Measurement Values
The measurement result is cleared as follows.
• Time Charts
FH
DI0 to DI6 signals
ON
DI7 signal
OFF
ON
BUSY signal
OFF
ON
READY signal
OFF
ON
ACK signal
OFF
FZ5
DI0 to DI6 signals
ON
DI7 signal
OFF
ON
BUSY signal
OFF
ON
READY signal
OFF
• Output Signals
Signal
Turns OFF when the command to clear the measurement value is being executed. Turns OFF as long
READY
as the BUSY signal is ON.
Turns ON when the measurement value is being cleared. The amount of time during which the BUSY
BUSY
signal is turned ON is approximately 1 ms.
ACK (FH only)
Turn ON when execution of the DI command is completed.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
0
1000000
Allow at least 1 ms and then turn ON IN7.
0
1000000
The signal is turned OFF when the
BUSY signal turns ON.
Allow at least 1 ms
and then turn ON IN7.
The PLC (user) turns OFF the
signal again when the ACK
signal is turned ON.
The signal turns OFF when
DI7 turns OFF.
Description
Parallel Communications
2
343