Note
To execute a measurement trigger after changing the scene, first confirm that the Command Completion (FLG)
signal and the BUSY signal that turned ON for execution of the Select Scene command have turned OFF.
Also, if the BUSY signal is ON for too little time and the external device cannot read it, increase the time that the
BUSY signal is ON for changing scenes so that the external device can read the ON state. To do this, change the
[Add time] setting for the [Scene switch time]. Refer to
during Measurement in the Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
9
The Sensor Controller executes measurement processing and turns ON the BUSY
signal when the request is received.
10
The Command Completion (FLG) signal is turned ON.
11
The PLC (user) turns OFF the Command Request (EXE) signal when the Command
Completion (FLG) signal turns ON.
12
When the Sensor Controller detects that the Command Request (EXE) signal is OFF, it
automatically turns OFF the Command Completion (FLG) signal and the BUSY signal.
*1:
A timeout error occurs and the Command Completion (FLG) signal and BUSY signal are forced OFF if the
Command Request (EXE) signal is not turned OFF from the PLC (user) within the time set in the PLC Link
settings ([Retry interval] for Ethernet PLC Link and RS-232C/422 PLC Link).
208
Communicating with PLC Link
Setting the Conditions That Are Related to Operation
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)