Event name
Output Control Timeout for EtherCAT
Meaning
A timeout occurred in data output handshaking control for measurement results.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
EtherCAT NET RUN
Indicators
Variable
System-defined
variables
None
Assumed cause
The data output handshaking controls
in the program (i.e., the ON/OFF tim-
Cause and
ing of the Result Set Request signal)
correction
are not correct.
The output control timeout time is too
short in comparison with the program
processing time.
Attached
None
information
Precautions/
This error occurs when measurement results are output on EtherCAT. For parallel I/O, PLC Link, or EtherNet/IP, refer to
Remarks
the Output Control Timeout for Parallel I/O, PLC Link, or EtherNet/IP event.
Event name
Logging Disk Write Error
Meaning
Writing data to the logging disk failed.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
EtherCAT NET RUN
Indicators
Variable
System-defined
variables
None
Assumed cause
A logging disk is not inserted.
The available space on the logging
Cause and
disk is not sufficient.
correction
There is no logging folder.
Security restrictions are set on the log-
ging disk.
Attached
None
information
Precautions/
This event occurs only for image logging/operation logging.
Remarks
Data logging does not trigger this event.
106
EtherCAT Connections (FH-1000 series/FH-3000 series only)
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
Correction
Correct the data output handshaking
controls in the program (i.e., the ON/
OFF timing of the Result Set Request
signal).
Correct the timeout time so that it is
suitable for the program processing
time.
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
Correction
Insert a logging disk.
Delete unnecessary files from the log-
ging disk or otherwise increase the
available space.
Create the logging folder or change
the logging folder.
Clear the security restrictions on the
logging disk.
Event code
5822 0000 hex
Slave
Detection timing
Error reset (after
resetting the error
Log category
in the slave)
Data is not output to the EtherCAT master and it is stored
in the Sensor. When the Result Set Request signal turns
ON, the stored data is output to the EtherCAT master.
EtherCAT LINK/ACT
---
Name
---
Prevention
Write suitable data output handshak-
ing controls in the program (i.e., the
ON/OFF timing of the Result Set
Request signal).
Set the timeout time so that it is suit-
able for the program processing time.
Event code
7819 0000 hex
Slave
Detection timing
Error reset (after
resetting the error
Log category
in the slave)
Logging will not be possible until the problem is corrected.
EtherCAT LINK/ACT
---
Name
---
Prevention
Insert the logging disk so that it will not
come out.
Delete unnecessary files from the log-
ging disk or otherwise increase the
available space.
Create the logging folder or change
the logging folder.
Clear the security restrictions on the
logging disk.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
At measurement
result output
System
---
---
When logging
images and log-
ging operations
System
---
---

Advertisement