Omron FH series User Manual page 160

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Sub-index 6: User Input Area 5 (User Input Area 5)
Setting range: -
Size: 8bytes (Double)
• Saves the User Input Area.
8000 hex
Sub-index0: Number of notice
Range: −
Size: 1 byte (U8)
Sub-index1: Switch of handshake mode
Range: −
Size: 1 bit (BOOL)
Sub-index2: Result Valid period
Range: −
Size: 4 bytes (INT32)
Sub-index3: Result Notification Time
Range: −
Size: 4 bytes (INT32)
Objects are provided for each line as shown below when more than one line is used.
Line 1 : 6010 hex (Status Signals) to 6016 hex (Image Processing Results Real Number Data)
7010 hex (Control Signals) to 7012 hex (Command Parameter)
8010 hex (Image Processing Results Output Settings)
Line 2 : 6020 hex (Status Signals) to 6026 hex (Image Processing Results Real Number Data)
7020 hex (Control Signals) to 7022 hex (Command Parameter)
8020 hex (Image Processing Results Output Settings)
Line 3 : 6030 hex (Status Signals) to 6036 hex (Image Processing Results Real Number Data)
7030 hex (Control Signals) to 7032 hex (Command Parameter)
8030 hex (Image Processing Results Output Settings)
Line 4 : 6040 hex (Status Signals) to 6046 hex (Image Processing Results Real Number Data)
7040 hex (Control Signals) to 7042 hex (Command Parameter)
8040 hex (Image Processing Results Output Settings)
Line 5 : 6050 hex (Status Signals) to 6056 hex (Image Processing Results Real Number Data)
7050 hex (Control Signals) to 7052 hex (Command Parameter)
8050 hex (Image Processing Results Output Settings)
Line 6 : 6060 hex (Status Signals) to 6066 hex (Image Processing Results Real Number Data)
7060 hex (Control Signals) to 7062 hex (Command Parameter)
8060 hex (Image Processing Results Output Settings)
Line 7 : 6070 hex (Status Signals) to 6076 hex (Image Processing Results Real Number Data)
7070 hex (Control Signals) to 7072 hex (Command Parameter)
8070 hex (Image Processing Results Output Settings)
158
EtherCAT Connections (FH-1000 series/FH-3000 series only)
Unit: -
Access: RO
Result Reporting Configuration
Unit: −
Access: RO
Unit: −
Access: RW
Unit: −
Access: RW
Unit: −
Access: RW
Default: 00000000Hex
PDO map: Possible
Default: 03 hex
PDO map: Not possible
Default: 00 hex
PDO map: Not possible
Default: 02 hex
PDO map: Not possible
Default: 01 hex
PDO map: Not possible
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)