3
Select one of the following Communications Modules based on the communications method
that is used to connect with the Sensor Controller and the Unit to connect to, then click
[Apply].
Communications Module
Serial (Ethernet)
PLC Link (SYSMAC CS/CJ/CP/One)(UDP)
PLC Link (SYSMAC CS/CJ/CP/One)(TCP)
PLC Link (MELSEC QnU/Q/QnAS)(UDP)
PLC Link (MELSEC QnU/Q/QnAS)(TCP)
PLC Link (JEPMC MP)
Serial (RS-232C/422)
PLC Link (SYSMAC CS/CJ/CP/One)
PLC Link (MELSEC QnU/Q/QnAS)
Note
• Normally select UDP communication module when serial is set as Ethernet.
Select TCP communication module if that is the recommended method for your particular communication environment.
4
Click the [Data save] button in the Toolbar.
5
On the Main Window, select [Function] − [System restart].
Click [OK] in the [System restart] dialog box to restart the Sensor Controller.
6
When the Sensor Controller has restart, operation will be performed for the default settings of
the specified Communications Module.
Set the IP address and other settings for the PLC or other external device.
IMPORTANT
After you set the Communications Module, always click [Data save] and then restart the Sensor Controller. If the
settings are not saved and the Sensor Controller is not restarted, the new Communications Module settings will not
be enabled.
Note
You can save the Communications Module settings to a file.
Select [Save to file] from the [Function] menu, and then select [System data] or [System + Scene group 0 data] to
save the settings data to a file.
Refer to
Saving Settings Data to the Controller RAM Disk or an External Memory Device in the Vision System FH/
FZ5 Series User's Manual (Cat. No. Z365).
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Description
Performs PLC Link communications via an Ethernet connection.
Select this Communications Module to UDP communicate with
an OMRON PLC.
Select this Communications Module to TCP communicate with
an OMRON PLC.
Select this Communications Module to UDP communicate with a
Mitsubishi Electric PLC.
Select this Communications Module to TCP communicate with a
Mitsubishi Electric PLC.
Select this Communications Module to communicate with a
Yaskawa Electric PLC.
Performs PLC Link communications via an RS-232C/422 con-
nection.
Select this Communications Module to communicate with an
OMRON PLC.
Select this Communications Module to communicate with a
Mitsubishi Electric PLC.
Communicating with PLC Link