Omron FH series User Manual page 244

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Signal
FLG
Command Completion Bit
GATE
Data Output Completion Bit
BUSY
Command Busy Bit
OR
Overall Judgement
XFLG
Flow Command Completion Bit
XBUSY
Flow Command Busy Bit
XWAIT
Flow Command Wait Bit
RUN
Run Mode
ERROR
Error Signal
CMD-CODE
Command code
RES-CODE
Response code
RES-DATA
Response data
DATA0-7
Output data 0 to 7
User Input Area
User Input Area 0 to 5
0 to 5
242
Communicating with EtherNet/IP
Signal name
Function
Turns ON when command execution is completed.
Turns ON when data output is completed.
Turns ON when command execution is in progress.
Turns ON when the overall judgement result is NG.
(The OR signal is output when the checkbox for [Output] is
selected in the ADJUST window.)
Turns ON when execution of a command that was input during
the execution of fieldbus flow control has been completed (i.e.,
when XBUSY turns OFF).
Turns ON when execution of a command that was input during
execution of fieldbus flow control is in progress.
Turns ON when a command can be input during the execution
of fieldbus flow control.
Turns ON when the Sensor Controller is set to the Run Mode.
Turns ON when the Sensor Controller detects an error signal.
Returns the executed command code.
Stores the response from the executed command.
Stores the response data from the executed command.
Outputs the data set in the output processing items.
When there are multiple processing items, data is overwritten
to this area while handshaking is performed.
The FH Sensor Controller writes in data defined by you in this
area using Macro customize functions.
• Data type of User Output Area 0 to 3 is DINT.
Data type of User Output Area 4 to 5 is LREAL.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)