Omron FH series User Manual page 377

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
1000
+3
0020
+4
-
+5
-
+6
-
+7
-
Acquiring Scene Group Number
Acquires the current scene group No.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
2000
+3
0020
Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
2000
+3
0020
+4
-
+5
-
+6
-
+7
-
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Bit
12 to 15
8 to 11
4 to 7
0001
0000
0000
0000
0000
0010
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0010
0000
0000
0000
0000
0010
Bit
12 to 15
8 to 11
4 to 7
0010
0000
0000
0000
0000
0010
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0000
Response data
Acquired scene No.
0000
0 to 3
0000
Command code
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0000
Response data
Acquired scene group No.
0000
Description
Description
Description
Command Control
3
375

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents